Abort Switch

DESCRIPTION

  • UL864 and FM listed
  • High brightness LEDs
  • Detailed indication of the status of the control panel
  • Supervised data connection
  • Countdown timer shows time remaining until release
  • Manual only and Automatic & Manual mode select keyswitch option
  • Four wire connection (data and power)
  • Protected dual action manual release switch option
  • Option for zonal fire and trouble indication with buzzer
  • Robust, high quality enclosure
  • Easy access to terminals
  • Remote Auto/Manual door interlock input (supervised)
  • Remote Abort input (supervised)
  • Internal trouble diagnosis indicators

SPECIFICATION

Construction1.2mm mild sheet steel
IP RatingIP30
Colour – lid & boxRed (optional grey)
Power supply21 to 30 V DC
Maximum current draw0.07A
Max. number of status units7
Quiescent current0.033A
Cable capacity2.5mm² per terminal
Monitored inputs end
of line resistor
6K8 0.5W Resistor
Monitored inputs
normal threshold
8K ohm to 1K ohm
Monitored inputs
trigger threshold
700 ohms to 100 ohms
Monitored inputs99 ohms to 0 ohms
Data connectionTwo wire RS485 connection
(max 1200 metres)
Construction1.2mm mild sheet steel
IP RatingIP30
ColourRed (optional grey)
Switch rating1A at 30V DC
Trigger resist470R 1W
End of line resistor6K8 1/2 W

Heat Detector

DESCRIPTION

SHIELD Heat Detector monitors temperature by using a dual thermistor network which provides a voltage output proportional to the external air temperature. There are nine heat detectorsin the series range designed to suit a wide variety of operating conditions.

FEATURES

  • Can be used for applications where smoke detectors are unsuitable
  • Ideal environments that are dirty or smoky under normal conditions
  • Wide operating voltage
  • Flashing LED option
  • Flashing LED and magnet operated test switch option

Smoke Detector

DESCRIPTION

SHIELD Photo-Electric Smoke Detector incorporates a pulsing LED located within the housing of the detector. The detector housing is identical to that of the Ionization Detector but has an indicator LED which is clear in quiescent state but produces red light in alarm.

FEATURES

  • Responds well to slow-burning, smoldering fires
  • Well suited for bedrooms and escape routes
  • Unaffected by wind or atmospheric pressure
  • Wide operating voltage
  • Flashing LED option
  • Flashing LED and magnet operated test switch option

Control Panel

DESCRIPTION

Designed and manufactured to the highest standards in a quality controlled environment and with UL & FM approvals, the Shield A-XT releasing panel offers outstanding value and performance for all small to medium fixed firefighting installations.

With three detection zones as standard, extinguishant release can be configured to activate from any combination of detection zone inputs to allow ( among other combinations) any two from three type activations such as would be required for detection in ceiling void, room and floor void applications.

The extensive configuration options of the Shield A-XT allow the functionality of the system to be extensively modified.

The panel contains a large LED display to enable easy configuration and control which also displays the time remaining until extinguishant release for added user safety.

The countdown timer is duplicated on up to seven remote status units to provide local indication of the system status..

With all of the electronics mounted on a single, easily removable, steel plate Shield A-XT panels are both robust and easy to install..

Shield A-XT is supplied in an enclosure that matches the design and colour of the elite RS range and is available in standard red or optional grey

SPECIFICATION

Construction1.2mm mild sheet steel
IP RatingIP30
FinishEpoxy powder coated
Colour – lid & boxRed RAL 3002 (optional grey
BS 00 A 05 semi-matt)
Mains supply230V AC or 115V AC
Mains supply fuse1.6 Amp (F1.6A L250V)
Power supply rating3 Amps total including battery charge 28V +/- 2V
Maximum ripple current200 millivolts
Battery type (Yuasa NP)Two 12 Volt 7Ah sealed lead acid in series
Battery charge voltage27.6VDC nominal
(temperature compensated)
Battery charge current0.7A maximum
Battery fuse20mm, 3.15A glass
Maximum current draw from batteries3 Amps
Quiescent current of panel in mains fail0.095A
R0V outputFused at 500mA
with electronic fuse
Sounder outputs24V Fused at 500mA with electronic fuse
Fault relay contact rating30VDC 1A Amp maximum
Fire relay contact rating30VDC 1A Amp maximum
Local fire relay contact rating30VDC 1A Amp maximum
First stage contact rating30VDC 1A Amp maximum
Second stage contact rating30VDC 1A Amp maximum
Extract contact rating30VDC 1A Amp maximum
Zone quiescent current2mA maximum
Terminal capacity12 AWG
Number of detectors per zoneDependent on type (maximum 32)
NAC rating0.5A per circuit
Detection circuit end of line6K8 5% ½ Watt resistor
Monitored input end of line6K8 5% ½ Watt resistor
Sounder circuit end of line10K 5% ¼ Watt resistor
Extinguishant output EOL1N4004 Diode
No. of initiating circuits3
No. of NAC circuits2 x 1st Stage, 1 x 2nd Stage
Extinguishant release outputFused at 1 Amp
Extinguishant release delayAdjustable 0 to 60 seconds (in 5 second steps)
Extinguishant release durationAdjustable 60 to 300 seconds (in 5 second steps)
SIL, AL, FLT, RST inputsSwitched -ve, max resistance 100 Ohms
Zone normal threshold8K ohms to 1K ohm
Detector alarm threshold999 ohms to 400 ohms
Call point alarm threshold399 ohms to 100 ohms
Short circuit threshold99 ohms to 0 ohms
Monitored inputs normal threshold8K ohms to 1K ohm
Monitored inputs alarm threshold999 ohms to 100 ohms
Monitored inputs Short circuit threshold99 ohms to 0 ohms
Status unit/Ancillary board connectionTwo wire RS485 connection
Status unit power outputFused at 500mA with electronic fuse

Panels

Product CodeDescriptionSize (mm)
S115R-EXTSurface mounting panel – Red 115V368 x 310 x 90
S230R-EXTSurface mounting panel – Red 230V368 x 310 x 90
S115G-EXTSurface mounting panel – Grey 115V368 x 310 x 90
S230G-EXTSurface mounting panel – Grey 230V368 x 310 x 90

FEATURES

  • UL864 and FM listed
  • Three initiation circuits as standard
  • Any single zone or any combinations of zones can be configured to release
  • Configurable first stage NAC delays
  • Configurable detection delays
  • Zero time delay upon manual release option
  • Compatible with I.S. barriers
  • Non-latching zone input option to receive signals from other systems such as aspirating equipment
  • Configurable extinguishant delays up to 60 seconds in 5 second steps
  • Configurable extinguishant duration up to 5 minutes in 5 second steps
  • Countdown timer shows time remaining until release
  • Supports up to seven, four wire status indicators
  • Built in Extract Fan control

HFC-227ea (FM-200) Fire Suppression System

DESCRIPTION

NAFFCO HFC-227ea engineered fire extinguishing systems manufactured and designed by NAFFCO are developed as heavy duty, reliable equipment and easy to mount.

NAFFCO-227 360-psi Modular (Single Cylinder) Systems

A 360-psi modular system is a single cylinder system using welded cylinders from 67 to 592 lbs. pressurized with Nitrogen at 360 psi. It includes cylinder, dip tube, discharge valve with pressure gauge/switch, manual level release and the solenoid electrical actuator. The agent flows from the cylinder through a hose into the pipework, which ends with one or more nozzles.

NAFFCO-227 360-psi Centralized (Up to Three Cylinders) System

A 360-psi centralized system is a multiple cylinder system using welded cylinders from 67 lbs. to 590 lbs. pressurized with Nitrogen at 360 psi. For system using up to three cylinders, the first cylinder (master cylinder) is equipped with a manual level release and a solenoid electrical actuator and operates all the other (auxiliary) cylinders. All the cylinders must be filled with the same amount of agent. For centralized systems using cylinders of 190 lbs., 300 lbs., 430 lbs., and 590 lbs. the pressure in the master cylinder is directoed to the pneumatic head with rapture disc mounted on top of each auxiliary cylinder valve through a line of high-pressure hoses.

NAFFCO-227 360-psi Centralized (More Than Three Cylinders) System

A 360-psi centralized system with more than three cylinders is operated by a 3-liter pilot cylinder filled with Nitrogen pressurized at 1,450 psi. The pilot cylinder is equipped with both manual level release and solenoid electrical actuator. The pressure from the pilot cylinder is directed toward the auxiliary cylinder pneumatic heads through a line of hoses and bursts the discs of pneumatic cones. A single pilot cylinder can operated up to 40 cylinders.

NAFFCO-227 600-psi Modular (Single Cylinder) Systems

A 600-psi modular system is a single cylinder system using seamless cylinders from 12 lbs. to 300 bls. pressurized with Nitrogen at 600 psi. It inclused cylinder, dip tube, discharge valve with pressure gauge and switch, manual lever release and solenoid electrical actuator. The agent flows from the cylinder through a hose into the pipework, which ends with one or more nozzles.

NAFFCOInert® Inert Gas System

DESCRIPTION

NAFFCOInert®… FOUR Gasses, ONE System

The NAFFCOInert® Fire Suppression System are safe, clean and a natural way to extinguish fire. NAFFCOInert® offers IG01, IG100, IG55 and IG541 Gasses with all the components needed to configure a complete system for 200/300 bar inert gas extinguishing agent. Full range of cylinders with 67, 80 and 140 litre capacities.

What is Inert Gas?

Inert Gas is a colorless, odorless, electrically nonconductive gas with a density approximately the same as air. Inert Gas is stored as pressurized gas within the cylinder assembly. When discharged into a protected space, it is clear and does not obscure vision. It leaves no residue and has zero ozone depleting potential and zero global warming potential.

  • IG01 – 100% Argon
  • IG100 – 100% Nitrogen
  • IG55 – 50% Argon+ 50% Nitrogen
  • IG541- 52% Nitrogen+ 40% Argon+ 8% CO2

CO2 Fire Suppression System

DESCRIPTION

CO2 is an odorless, colorless, electrically non-conductive, non-corrosive, and non-deteriorating agent. It is normally present in the atmosphere at about 0.03% by volume.

CO2 System consists of a fixed supply of CO2 converted through a piping network and nozzles.

Total Flooding extinguishers both surface and deep seated fires by discharging gas onto the enclosed space.

Local Application system is used for non-enclosable areas (2 or 3 Dimensional hazards):

  • Flammable liquid storage areas
  • Spray Booth
  • Electrical areas
  • Dust Collection
  • Engine Room
  • Machine Parts

Pre-Engineered Kitchen Suppression System

DESCRIPTION

The Kitchen Fire Suppression System Kit for Kitchen is a pre-engineered, wet chemical, indirect low-pressuresystem with a fixed nozzle agent distribution network. It extinguishes cooking fires caused by grease orgrease-laden vapors (class F or class K fire). It does not require electrical power or connection to either domesticwater supply or fire sprinkler supply lines. In case of fire, the system actuates automatically or by manual release.The Kitchen Fire Suppression System Kit for Kitchen is designed for the fire protection during cooking operations.Cooking operations are defined as kitchens that have Cooking appliances that produce grease and grease-ladenvapors. Cooking appliances include flat grills, char broilers, woks, cooking plates and deep fat fryers. Three (3),Five (5) and Ten (10) nozzles are included in the Kitchen Fire Suppression System Kit for Kitchen. One nozzleprotects an area of approximately 1m2 and extinguishes for example a fire caused by a burning 45 liter deep fatfryer. We recommend installing one (1) nozzle for the protection of the hood, one nozzle for the protection ofplenum and other nozzles for the protection of cooking appliances that produce grease and grease-laden vaporsas applicable depending on size of the kitchen equipment’s.

The system design complies with LPC 1223 Standards.

The various cylinder sizes 9L, 15L & 22.5L with different flow capacity are available

Heat Sensor tube Automatic activation

Fire is detected by the flexible, heat-sensitive, nitrogen pressurized Kitchen Fire Suppression System sensor tubing, which must be routed throughout the hazard area.

Fusible Link Automatic activation

Fire is detected by the Fusible Link which must be routed throughout the hazard area. In case of fire, the Fusible Link in Kitchen fire Suppression System breaks & tension reduces suddenly and activates the system automatically.

Types of System Activation

  • By Heat Sensor tube
  • By Fusible Link

Kitchen Hood Wet Chemical Fire Suppression System

DESCRIPTION

Wet chemical suppression system is used to protect modern commercial kitchen from potential threats like open flame, red hot cooking surface and heavily grease laden environment which in turn leads to oil and grease fires.

The system design complies with NFPA 96 and NFPA 17A Standards.

The various cylinder sizes Model NF-KS5, NF-KS10, NF-KS15 and NF–KS20 with different flow capacity are available

APPLICATIONS

  • Restaurant Hoods
  • Plenums
  • Filters
  • Ducts
  • Cooking appliances like deep fat fryers, range tops, upright broilers, rock char broilers, gas radiant char broilers and woks

Alarm Check Valve Assembly

DESCRIPTION

The alarm check valve is a water flow alarm device designed for vertical installation in the main supply to a wet pipe sprinkler system. When a flow of water from the system equals or exceeds that of a single sprinkler, the valve is to actuate a fire alarm.

SPECIFICATION

  • Nominal Size : 80,100, 150 & 200 NB
  • Maximum Working Pressure : 17.5 Bar (250 Psi)
  • Mounting : Vertical

Dry Type Pillar Fire Hydrants

DISCRIPTION

  • NAFFCO Fire Hydrants are designed to comply with ANSI/AWWA C502.
  • Dry barrel design eliminates damage to the hydrant caused by freezing of the upper part.
  • NAFFCO Fire Hydrants are designed for high performance and easy to install, maintain and repair.
  • Excellent and proven flow characteristics.
  • 2 x 2½” NH thread connectors for soft hose connection.
  • 1 x 4½” NH thread pumper connection for fire trucks.
  • 6” inlet connection complying to mechanical joint ANSI/AWWA C111/A21.11 or flange connection ASME B16.5 Class 150.
  • Operation threads are corrosion protected and for easy operation.
  • NAFFCO fire hydrants are high pressure rated to 250 psi compatible with today’s trends.
  • Internal epoxy paint system gives high corrosion protection to hydrants.
  • Advanced safety couplings and flange design reduces traffic damage to hydrant.
  • Main valve is easily removed from either the bonnet flange or ground line flange.

SPECIFICATION

  • Body Material: Ductile Iron.
  • Nominal Pressure 250 psi., Test Pressure: 500 psi.
  • O-ring sealed flanges at the bonnet ground line and shoe simplify maintenance by eliminating gasket adhesion at these points, making disassembly easier. The O-rings are easier than flat gaskets to position during reassembly, and provide superior pressure handling.
  • Hold-down nut – features integral weather seal. Prevents unauthorized removal of hold-down nut or operating nut. Resilient wiper seal prevents water entry and protects from freezing; material resistant to sunlight deterioration. O-ring provides second level seal.
  • Safety flange – breaks cleanly to help prevent barrel damage, but strong enough to withstand normal handling. Allows economical repair, adding of extension section, rotation or changing of upper barrel without excavation.
  • Full flow openings – large, smooth radius hose and pumper openings reduce friction loss.
Fire Hose Reel, Nozzles, Hoses and Accessories> Hydrant Valves & Risers

    array(8) { ["_vc_post_settings"]=> array(5) { [0]=> string(30) "a:1:{s:10:"vc_grid_id";a:0:{}}" [1]=> string(30) "a:1:{s:10:"vc_grid_id";a:0:{}}" [2]=> string(30) "a:1:{s:10:"vc_grid_id";a:0:{}}" [3]=> string(30) "a:1:{s:10:"vc_grid_id";a:0:{}}" [4]=> string(30) "a:1:{s:10:"vc_grid_id";a:0:{}}" } ["slide_template"]=> array(1) { [0]=> string(7) "default" } ["_wpb_vc_js_status"]=> array(1) { [0]=> string(4) "true" } ["_custom_page_options"]=> array(6) { [0]=> string(32) "a:1:{s:7:"sidebar";s:5:"right";}" [1]=> string(32) "a:1:{s:7:"sidebar";s:5:"right";}" [2]=> string(32) "a:1:{s:7:"sidebar";s:5:"right";}" [3]=> string(32) "a:1:{s:7:"sidebar";s:5:"right";}" [4]=> string(32) "a:1:{s:7:"sidebar";s:5:"right";}" [5]=> string(32) "a:1:{s:7:"sidebar";s:5:"right";}" } ["_dp_original"]=> array(1) { [0]=> string(4) "1152" } ["_edit_lock"]=> array(1) { [0]=> string(12) "1538116688:1" } ["_edit_last"]=> array(1) { [0]=> string(1) "1" } ["_thumbnail_id"]=> array(1) { [0]=> string(4) "1363" } }